Water Quality Sensors

DEC890

Digital Conductivity Sensor

A digital conductivity sensor that measures conductivity and temperature.

DEC890is a digital sensor that measures conductivity and temperature using a two-electrode graphite design.

Suitable for the metals, electronics, mining, paper, and semiconductor industries.

Supports pipeline, immersion, and flow cell installation at wastewater treatment plants, water treatment plants, and monitoring stations.

Specifications

Measured ParametersConductivity, Temperature
Measurement PrincipleTwo graphite electrodes
Measurement RangeConductivity: 0~10 mS/cm / Temperature: 0.0~50.0 °C
ResolutionConductivity: 0.01 μS/cm / Temperature: 0.1 °C
Accuracy±1% of range
Operating Temperature0~50 °C
Operating Pressure0~6 bar
Ingress ProtectionIP68
Power RequirementsDC 12 V
Power ConsumptionApprox. 0.2 W
Electrical IsolationIsolation between power supply and communication circuits
Communication ProtocolRS485 Modbus-RTU
Temperature CompensationAutomatic or manual compensation
Calibration MethodOffset, factor, and multipoint calibration
Calibration & MaintenanceVisual inspection: monthly / Calibration check: monthly (depending on operating conditions) / Seal maintenance: every two years
Installation TypePipeline, immersion, flow cell
Dimensions37 mm diameter / Approx. 261 mm overall length
Materials316 stainless steel / POM
CableStandard 10 m / Custom lengths available

A better approach to water quality management starts with Water Eyes.

Prompt, accurate responses to product inquiries and technical questions.