Products

Water Quality Sensors
OPD790
Digital DO Sensor
A digital DO sensor that measures dissolved oxygen, oxygen saturation, and temperature.
Product Overview
OPD790is a digital sensor that measures dissolved oxygen, oxygen saturation, and temperature using fluorescence quenching.
Requires no minimum flow velocity or electrolyte replacement.
Supports immersion and pipeline installation.
Specifications
| Measured Parameters | Dissolved oxygen, Oxygen saturation, Temperature |
|---|---|
| Measurement Principle | Fluorescence quenching |
| Measurement Range | Dissolved oxygen: 0.00~20.00 mg/L / Saturation: 0~200% / Temperature: 0.0~50.0 °C |
| Response Time | 0→100%: T90 <25 s / 100→0%: T90 <30 s |
| Resolution | Dissolved oxygen: 0.01 mg/L / Saturation: 1% / Temperature: 0.1 °C |
| Accuracy | Dissolved oxygen: ±0.1 mg/L / Saturation: ±1% / Temperature: ±0.2 °C |
| Operating Temperature | 0~50 °C |
| Storage Temperature | -10~60 °C |
| Operating Pressure | ≤3 bar |
| Ingress Protection | IP68 |
| Power Requirements | DC 12 V |
| Power Consumption | 0.2 W |
| Communication Protocol | RS485 MODBUS / Modbus-RTU |
| Temperature Compensation | Temperature, salinity, and barometric pressure compensation |
| Calibration Method | One-point / two-point / zero and full-scale calibration |
| Calibration & Maintenance | Visual inspection: monthly / Cleaning: weekly (depending on operating conditions) / Calibration check: monthly / Membrane cover replacement: every 12 months |
| Installation Type | Immersion, pipeline |
| Dimensions | 35 mm diameter / 250 mm overall length |
| Weight | Approx. 260 g (excluding cable) |
| Materials | Body shaft: PPS / Measuring head: Ti (titanium) |
| Cable | M16 |
A better approach to water quality management starts with Water Eyes.
Prompt, accurate responses to product inquiries and technical questions.